Study of available bone for interforaminal implant treatment using cone-beam computed tomography

  1. Cristina Madrigal Martínez-Pereda 1
  2. Ricardo Ortega Aranegui 1
  3. Cristina Meniz García 1
  4. Juan López Quiles 1
  1. 1 Universidad Complutense de Madrid
    info

    Universidad Complutense de Madrid

    Madrid, España

    ROR 02p0gd045

Revista:
Medicina oral, patología oral y cirugía bucal. Ed. inglesa

ISSN: 1698-6946

Año de publicación: 2008

Volumen: 13

Número: 5

Páginas: 8

Tipo: Artículo

Otras publicaciones en: Medicina oral, patología oral y cirugía bucal. Ed. inglesa

Resumen

Objectives: To analyze the availability of bone in the interforaminal region and to demonstrate the variation in diagnosis between panoramic x-ray and cone-beam computed tomography (CBCT). Material and methods: In 50 patients and in 5 areas of each, a series of parameters concerning available bone were measured on both the panoramic and the CT images. Results: Panoramic images underestimate the vertical and horizontal measurements when compared with CBCT. Regarding implant treatment, the interforaminal region presents the same remaining bone height throughout its full extent, the correlation between one side of the midline and the other was highly significant for all the parameters studied, and 20% of the sample showed some buccal and/or lingual concavity. Conclusion: Cone-beam CT is an advantageous system for interforaminal implant treatment planning, especially since the reported radiation dose is minimal and geometric accuracy is very high.