Evaluación de los signos de la pseudoexfoliación en el segmento anterior mediante tomografía de coherencia óptica y cámara de Scheimpflug

  1. J.I. Fernández-Vigo
  2. L. de-Pablo Gómez de Liaño
  3. I. Sánchez-Guillen
  4. A. Macarro-Merino
  5. C. Fernández-Vigo
  6. J. García-Feijóo
  7. J.A. Fernández-Vigo
Journal:
Archivos de la Sociedad Española de Oftalmologia

ISSN: 0365-6691

Year of publication: 2018

Volume: 93

Issue: 2

Pages: 53-59

Type: Article

DOI: 10.1016/J.OFTAL.2017.06.008 DIALNET GOOGLE SCHOLAR

More publications in: Archivos de la Sociedad Española de Oftalmologia

Abstract

Objective To evaluate different anterior segment parameters in eyes with pseudoexfoliation (PSX), fellow eyes, and controls using optical coherence tomography and a Scheimpflug imaging system. Methods Three groups were studied: 44 eyes of 44 patients with PSX, 30 clinically unaffected fellow eyes, and 148 eyes of 148 healthy controls. The anterior chamber depth and volume, corneal volume and thickness, pupil diameter and corneal densitometry were measured using a Scheimpflug imaging system (Pentacam, Oculus Inc.; Wetzlar, Germany). The angle width, the length and area of the trabecular meshwork, and the iris thickness were measured using an optical coherence tomography RTVue 100 device (Optovue, Fremont, CA, USA). The presence of PSX deposits was also assessed by OCT. Results There were no differences in the anterior chamber volume or depth in the corneal volume or central thickness (P ≥ .228). The corneal densitometry was similar between PSX and fellow eyes; however it was greater than in the control group (P < .001). As regards the parameters measured by OCT, there were no differences in the angle width or in the trabecular meshwork size between the 3 groups; however, the iris was thinner in controls (P = .005). In all patients the PSX deposits were correctly visualised by OCT after the identification by biomicroscopy. Conclusions There were no differences in the anterior segment biometric measurements between patients with PSX and controls, although the corneal densitometry and iris thickness were greater in the PSX and fellow eyes groups