Influence of short implants geometry on primary stability

  1. José González Serrano 1
  2. Pedro Molinero Mourelle 1
  3. Beatriz Pardal Peláez 1
  4. Luis Miguel Sáez Alcaide 1
  5. Ricardo Ortega Aranegui 1
  6. Juan López Quiles 1
  1. 1 Department of Dental Clinical Specialties. School of Dentistry, Complutense University, Madrid, Spain
Revista:
Medicina oral, patología oral y cirugía bucal. Ed. inglesa

ISSN: 1698-6946

Año de publicación: 2018

Volumen: 23

Número: 5

Páginas: 16

Tipo: Artículo

DOI: 10.4317/MEDORAL.22378 DIALNET GOOGLE SCHOLAR lock_openAcceso abierto editor

Otras publicaciones en: Medicina oral, patología oral y cirugía bucal. Ed. inglesa

Resumen

A correct design is needed in short implants to improve primary stability (PS) in low quality bone. This study aimed to compare PS of double thread and single thread short implants. Thirty implants with single thread design (PHI/SHORT-I) and 30 implants with double thread design (PHIA/SHORT-I) (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in 30 randomly selected bovine ribs. PS was assessed in implant stability quotients (ISQ) and periotest values (PV) with Osstell™ and Periotest® devices, respectively. Computed tomographies of the ribs were taken and bone quality was evaluated in Hounsfield Units (HU) using Ez3D Plus software (Vatech Co., Korea). Only implants placed in low quality bone according to Misch and Kircos classification were selected (D3 bone: 350-850 HU; and D4 bone: 150-350 HU). Ten implants were not included in the study for being placed in D1 and D2 bone. Finally, 50 implants were selected: 17 and 9 PHI/SHORT-I in D3 and D4 bone respectively, and 15 and 9 PHIA/SHORT-I in D3 and D4 bone respectively. The one-way ANOVA showed statistically significant differences in ISQ (61.35 ± 4.77 in PHI/SHORT-I and 66.43 ± 4.49 in PHIA/SHORT-I, P<0.005) and PV (-2.76 ± 0.8 and -4.11 ± 1.24 respectively, P<0.005) between two implant designs in D3 bone, and statistically significant differences in ISQ (53.44 ± 3.34 in PHI/SHORT-I and 60.56 ± 1.53 in PHIA/SHORT-I, P<0.0001) and PV (1.13 ± 0.95 and -2.5 ± 0.61 respectively, P<0.0001) between two groups in D4 bone. Double thread design short implants resulted to have higher PS in comparison with single thread design short implants in D3 and D4 bone.

Referencias bibliográficas

  • Arlin, M. (2006). Short dental implants as a treatment option: results from an observational study in a single private practice. Int J Oral Maxillofac Implants. 21. 769
  • Cannizzaro, G,Felice, P,Leone, M,Viola, P,Esposito, . (2009). Early loading of implants in the atrophic posterior maxilla: lateral sinus lift with autogenous bone and Bio-Oss versus crestal mini sinus lift and 8-mm hydroxyapatite-coated implants. A randomized controlled clinical trial. Eur J Oral Implantol. 2. 25-38
  • Felice, P,Soardi, E,Pellegrino, G,Pistilli, R,Marchetti, C,Gessaroli, . (2011). Treatment of the atrophic edentulous maxilla: short implants versus bone augmentation for placing longer implants. Five-month post-loading results of a pilot randomized controlled trial. Eur J Oral Implantol. 4. 191-202
  • Dursun, E,Keceli, HG,Uysal, S,Güngör, H,Muhtarogullari, M,Tözüm, T. (2016). Management of Limited Vertical Bone Height in the Posterior Mandible: Short Dental Implants Versus Nerve Lateralization With Standard Length Implants. J Craniofac Surg. 27. 578
  • Almeida, EO,Rocha, EP,Freitas Júnior, AC,Anchieta, RB,Poveda, R,Gupta, . (2015). Tilted and short implants supporting fixed prosthesis in an atrophic maxilla: a 3D-FEA biomechanical evaluation. Clin Implant Dent Relat Res. 17. 332
  • Nisand, D,Renouard, . (2014). Short implant in limited bone volume. Periodontol 2000. 66. 72-96
  • Srinivasan, M,Vazquez, L,Rieder, P,Moraguez, O,Bernard, JP,Belser, U. (2014). Survival rates of short (6 mm) micro-rough surface implants: a review of literature and meta-analysis. Clin Oral Implants Res. 25. 539-545
  • Tawil, G,Younan, . (2003). Clinical evaluation of short, machined-surface implants followed for 12 to 92 months. Int J Oral Maxillofac Implants. 18. 894-901
  • Gonçalves, TM,Bortolini, S,Martinolli, M,Alfenas, BF,Peruzzo, DC,Natali, . (2015). Long-term short implants performance: systematic review and meta-analysis of the essential assessment parameters. Braz Dent J. 26. 325
  • Bourauel, C,Aitlahrach, M,Heinemann, F,Hasan, . (2012). Biomechanical finite element analysis of small diameter and short dental implants: extensive study of commercial implants. Biomed Tech. 57. 21-32
  • Vairo, G,Sannino, . (2013). Comparative evaluation of osseointegrated dental implants based on platform-switching concept: Influence of diameter, length, thread shape, and in-bone positioning depth on stress-based performance. Comput Math Methods Med. 2013. 1-15
  • Roos-Jansåker, AM,Lindahl, C,Renvert, H,Renvert, . (2006). Nine- to fourteen-year follow-up of implant treatment. Part I: implant loss and associations to various factors. J Clin Periodontol. 33. 283-289
  • Möhlhenrich, SC,Heussen, N,Elvers, D,Steiner, T,Hölzle, F,Modabber, . (2015). Compensating for poor primary implant stability in different bone densities by varying implant geometry: a laboratory study. Int J Oral Maxillofac Surg. 44. 1514-1520
  • Cehreli, M,Sahin, S,Akça, . (2004). Role of mechanical environment and implant design on bone tissue differentiation: current knowledge and future contexts. J Dent. 32. 123
  • Jain, N,Gulati, M,Garg, M,Pathak, . (2016). Short Implants: New Horizon in Implant Dentistry. J Clin Diagn Res. 10. 14
  • Misch, CE,Kircos, L. (1999). Diagnostic imaging and techniques. In: Misch CE, ed. Contemporary Implant Dentistry. 2nd ed. Mosby. St. Louis.
  • de Oliveira, GJ,Barros-Filho, LA,Barros, LA,Queiroz, TP,Marcantonio E, J. (2016). In Vitro Evaluation of the Primary Stability of Short and Conventional Implants. J Oral Implantol. 42. 458
  • González-Serrano, J,Ortega-Aranegui, R,López-Quiles, . (2017). In vitro comparison of primary stability of two implant designs in D3 bone. Med Oral Patol Oral Cir Bucal. 22. 473
  • Herekar, M,Sethi, M,Ahmad, T,Fernandes, AS,Patil, V,Kulkarni, . (2014). A correlation between bone (B), insertion torque (IT), and implant stability (S): BITS score. J Prosthet Dent. 112. 805
  • Andreotti, AM,Goiato, MC,Nobrega, AS,Freitas da Silva, EV,Filho, HG,Pellizzer, E. (2016). Relationship Between Implant Stability Measurements Obtained by Two Different Devices: A Systematic Review. J Periodontol. 21. 1-13
  • Atieh, MA,Alsabeeha, NH,Payne, AG,de Silva, RK,Schwass, DS,Duncan, W. (2014). The prognostic accuracy of resonance frequency analysis in predicting failure risk of immediately restored implants. Clin Oral Implants Res. 25. 29-35
  • Bornstein, MM,Hart, CN,Halbritter, SA,Morton, D,Buser, . (2009). Early loading of nonsubmerged titanium implants with a chemically modified sand-blasted and acid-etched surface: 6-month results of a prospective case series study in the posterior mandible focusing on peri-implant crestal bone changes and implant stability quotient (ISQ) values. Clin Implant Dent Relat Res. 11. 338-347
  • Reich, W,Schweyen, R,Heinzelmann, C,Hey, J,Al-Nawas, B,Eckert, A. (2017). Novel expandable short dental implants in situations with reduced vertical bone height-technical note and first results. Int J Implant Dent. 3. 46
  • Primary and Secondary Stability of Single Short Implants. J Craniofac Surg.
  • Winter, W,Möhrle, S,Holst, S,Karl, . (2010). Parameters of implant stability measurements based on resonance frequency and damping capacity: a comparative finite element analysis. Int J Oral Maxillofac Implants. 25. 532
  • García-Vives, N,Andrés-García, R,Rios-Santos, V,Fernández-Palacín, A,Bullón-Fernández, P,Herrero-Climent, . (2009). In vitro evaluation of the type of implant bed preparation with osteotomes in bone type IV and its influence on the stability of two implant systems. Med Oral Patol Oral Cir Bucal. 14. 455-460
  • Valente, ML,de Castro, DT,Shimano, AC,Lepri, CP,dos Reis, A. (2016). Analyzing the Influence of a New Dental Implant Design on Primary Stability. Clin Implant Dent Relat Res. 18. 168-173
  • Gehrke, SA,da Silva, UT,Del Fabbro, . (2015). Does Implant Design Affect Implant Primary Stability? A Resonance Frequency Analysis-Based Randomized Split-Mouth Clinical Trial. J Oral Implantol. 41. 281-286
  • Griffin, TJ,Cheung, W. (2004). The use of short, wide implants in posterior areas with reduced bone height: a retrospective investigation. J Prosthet Dent. 92. 139-144
  • Karthikeyan, I,Desai, SR,Singh, . (2012). Short implants: a systematic review. J Indian Soc Periodontol. 16. 302-312