Aberraciones ópticas en ojos con lentes de contacto medidas con el sistema de trazado de Rayos

  1. V. Blázquez-Sánchez
  2. M.A. Mendoza-Pérez
  3. J.M. Merayo-LLoves
  4. R. Navarro-Belsué
Journal:
Archivos de la Sociedad Española de Oftalmologia

ISSN: 0365-6691

Year of publication: 2006

Volume: 81

Issue: 10

Pages: 575-579

Type: Article

DOI: 10.4321/S0365-66912006001000004 DIALNET GOOGLE SCHOLAR lock_openOpen access editor

More publications in: Archivos de la Sociedad Española de Oftalmologia

Abstract

Purpose: To evaluate the impact of disposable soft contact lenses upon visual performance by comparing the optical aberrations of myopic eyes with and without the use of contact lenses. Method: The optical aberrations of a set of 18 eyes were measured by a laser ray tracing system, an objective measurement method, enabling comparison of the findings of the naked eye, the eye plus a test lens, and the eye plus a disposable contact lens. Results: There was a large variability among subjects, but the general tendency was that test lenses did not modify aberrations, whereas contact lenses tended to increase the ocular aberrations for large pupils by an average of 40%. There was a lower increase for smaller pupils. Conclusion: This study predicts there will be no significant adverse effects on the quality of vision from the use of disposable contact lenses worn under daylight conditions, but a small decline in night vision.

Bibliographic References

  • Moreno-Barriuso, E, Lloves, JM, Marcos, S, Navarro, R, Llorente, L, Barbero, S. (2001). Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing. Invest Ophthalmol Vis Sci. 42. 1396-1403
  • Mrochen, M, Kaemmerer, M, Mierdel, P, Seiler, T. (2001). Increased higher-order optical aberrations after laser refractive surgery: a problem of subclinical decentration. J Cataract Refract Surg. 27. 362-369
  • Dietze, HH, Cox, MJ. (2004). Correcting ocular spherical aberration with soft contact lenses. J Opt Soc Am A Opt Image Sci Vis. 21. 473-485
  • Chateau, N, Blanchard, A, Baude, D. (1998). Influence of myopia and aging on the optimal spherical aberration of soft contact lenses. J Opt Soc Am A Opt Image Sci Vis. 15. 2589-2596
  • Lorente, A, Pons, AM, Malo, J, Artigas, JM. (1997). Standard criterion for fluctuations of modulation transfer function in the human eye: application to disposable contact lenses. Ophthalmic Physiol Opt. 17. 267-272
  • Pons, AM, Lorente, A, Albarran, C, Montes, R, Artigas, JM. (1998). Characterizacion of the visual performance with soft daily wear disposable contact lenses. Ophthalmic Physiol Opt. 18. 40-48
  • Torrents, A, Navarro, R, Losada, MA. (1995). El método de doble paso para evaluar la calidad óptica de la imagen retiniana. Ver y Oir. 97. 29-36
  • Artal, P, Marcos, S, Navarro, R, Williams, DR. (1995). Odd aberrations and double-pass measurements of retinal image quality. J Opt Soc Am A. 12. 195-201
  • Tomlinson, A, Mann, G. (1985). An analysis of visual performance with soft contact lens and spectacle correction. Ophthalmic Physiol Opt. 5. 53-57
  • Hong, X, Himebaugh, N, Thibos, LN. (2001). On-eye evaluation of optical performance of rigid and soft contact lenses. Optom Vis Sci. 78. 872-880
  • Cox, IG, Holden, BA. (1990). Soft contact lens-induced longal spherical aberration ad its effect on contrast sensitivity. Optom Vis Sci. 67. 679-683
  • Lorente, A, Albarran, C, Montes, R, Pons, AM, Artigas, JM. (1997). Contact lenses: do they really change the optical performance?. Cont Lens Anterior Eye. 20. 57-61
  • Navarro, R, Losada, MA. (1997). Aberration and relative efficiency of light pencils in the living human eye. Optom Vis Sci. 74. 540-547
  • Atchinson, DA. (1995). Aberrations associated with rigid contact lenses. J Opt Soc Am A. 12. 2267-2273
  • Dorronsoro, C, Barbero, S, Llorente, L, Marcos, S. (2003). On-eye measurement of optical performance of rigid gas permeable contact lenses based on ocular and corneal aberrometry. Optom Vis Sci. 80. 115-125
  • Collins, MJ, Brown, B, Atchison, DA, Newman, SD. (1992). Tolerance to spherical aberration induced by rigid contact lenses. Ophthalmic Physiol Opt. 12. 24-28
  • Hammer, RM, Holden, BA. (1994). Spherical aberration of aspheric contact lenses on eye. Optom Vis Sci. 71. 522-528
  • Kirkpatrick, DL, Roggenkamp, R. (1985). Effects of soft contact lenses contrast sensivity. Am Optom Phyisiol Opt. 62. 407-412
  • Moreno-Barriuso, E, Navarro, R. (2000). Laser Ray Tracing versus Hartmann-Shack sensor for measuring optical aberrations in the human eye. J Opt Soc Am A Opt Image Sci Vis. 17. 974-977
  • Gispets, I, Parcerisas, J. (2005). Aberraciones oculares: aspectos clínicos. ICM. Madrid.