Eco-fusión.Aplicación en el intervencionismo estructural cardíaco

  1. García Fernández , Miguel Ángel 1
  2. Carvajal Rivera, José Julián 1
  3. de Agustín , José Alberto 1
  4. Marcos-Alberca , Pedro 1
  5. Nombela Franco , Luis 1
  6. Jiménez Quevedo , Pilar 1
  7. Macaya Miguel , Carlos 1
  8. Pérez de Isla, Leopoldo 1
  1. 1 Instituto Cardiovascular Clínico. Hospital Universitario Clínico San Carlos. Madrid. Facultad de Medicina. Universidad Complutense de Madrid. Madrid. España
Journal:
Revista de Ecocardiografía práctica y otras Técnicas de Imagen Cardíaca (RETIC)

ISSN: 2529-976X

Year of publication: 2017

Issue Title: Journal of Practical Echocardiography and Other Cardiac Imaging Techniques

Issue: 4

Pages: 9-15

Type: Article

DOI: 10.37615/RETIC.N4A3 DIALNET GOOGLE SCHOLAR lock_openOpen access editor

More publications in: Revista de Ecocardiografía práctica y otras Técnicas de Imagen Cardíaca (RETIC)

Abstract

The evolution in percutaneous structural intervention has generated a parallel development in advanced imaging techniques. Echocardiography plays a key role in structural intervention in patient selection, assessment during the fluoroscopy and immediate analysis of outcomes and early detection of complications; echo-fusion images appear as a complementary tool in which two techniques with dynamic images are complemented in a single image in order to guide, decrease intervention time and reduce complications.

Bibliographic References

  • Clegg S, Salcedo E, Quaife R, Carrol J. Imaging in structural heart disease. En: Lasala J, Rogers J. Interventional procedures for adult and structural heart disease. 1.ª ed. Elsevier-Saunders, 2014; 7-28.
  • Carminati M, Agnifili M, Arcidiacono C, et al. Role of imaging in interventions on structural heart disease. Expert Review of Cardiovascular Therapy 2013; 11: 1659-1676. DOI: https://doi.org/10.1586/14779072.2013.854166
  • Perk G, Lang RM, García-Fernández MA, et al. Use of real time three-dimensional transesophageal echocardiography in intracardiac catheter based interventions. J Am Soc Echocardiogr 2009; 22 (8): 865-882. DOI: https://doi.org/10.1016/j.echo.2009.04.031
  • Thaden J, Sanon S, Geske J, et al. Echocardiographic and fluoroscopic fusion imaging for procedural guidance: An overview and early clinical experience. Journal of American Society of Echocardiography 2016; 29: 503-512. DOI: https://doi.org/10.1016/j.echo.2016.01.013
  • Gaemperli O, Schepis T, Kalff V, et al. Validation of a new cardiac image fusion software for three-dimensional integration of myocardial perfusion SPECT and stand-alone 64-slice CT angiography. European Journal of Nuclear and Medicine Molecular Imaging 2007; 34: 1097-1106. DOI: https://doi.org/10.1007/s00259-006-0342-9
  • White JA, Fine N, Gula LJ, et al. Fused whole-heart coronary and myocardial scar imaging using 3-TCMR. Implications for planning of cardiac resynchronization therapy and coronary revascularization. JACC Cardiovascular Imaging 2010; 3: 921-930. DOI: https://doi.org/10.1016/j.jcmg.2010.05.014
  • Tanis W, Scholtens A, Habets J, et al. CT angiography and (1)(8)FFDG-PET fusion imaging for prosthetic heart valve endocarditis. JACC Cardiovascular Imaging 2013; 6: 1008-1013. DOI: https://doi.org/10.1016/j.jcmg.2013.07.004
  • Arujuna A, Housden R, Ma Y, et al. Novel system for real-time integration of 3D-Echocardiography and fluoroscopy for image guided cardiac interventions: preclinical Validation and clinical feasibility evaluation. IEEE Journal of traslational engineering in health and medicine 2014; 2: 110. DOI: https://doi.org/10.1109/JTEHM.2014.2303799
  • Balzer J, Zeus T, Hellhammer K, et al. Initial clinical experience using the Echonavigator® – system during structural heart disease interventions. World Journal of Cardiology2015; 7 (9): 562-570. DOI: https://doi.org/10.4330/wjc.v7.i9.562
  • Feldman T, Hellig F, Mollman H. Structural heart interventions: the state of the art and beyond. Eurointervention 2016; 12: X6. DOI: https://doi.org/10.4244/EIJV12SXA1
  • Palacios I, Arzamendi D. Intervencionismo en cardiopatía estructural. Más allá de la terapia valvular transcateter. Revista española de cardiología 2012; 65 (5): 405-413. DOI: https://doi.org/10.1016/j.recesp.2011.12.022
  • Afzal S, Veulemans V, Balzer J, et al. Safety and efficacy of trans-septal puncture guided by real-time fusion of echocardiography and fluoroscopy. Netherland Heart Journal. Neth Heart J 2017; 25 (2): 131-136. DOI: https://doi.org/10.1007/s12471-016-0937-0
  • Vahanian A, Alfieri O, Andretti F, et al, ESC Committee for Practice Guidelines (CPG); Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC); European Association for Cardio-Thoracic Surgery (EACTS). Guidelines on the management of valvular heart disease: the Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). European Journal of Car- diothoracic Surgery 2012; 42: S1-44.
  • Sundermann S, Biaggi P, Grunenfelder J, et al. Safety and feasibility of novel technology fusing echocardiography and fluoroscopy images during Mitraclip interventions. Eurointervention 2014; 9: 1210-1216. DOI: https://doi.org/10.4244/EIJV9I10A203
  • García-Fernández MA, Cortés M, García-Robles JA, et al. Utility of real-time three-dimensional transesophageal echocardiography in evaluating the success of percutaneous transcatheter closure of mitral paravalvular leaks. J Am Soc Echocardiogr 2010; 23 (1): 26-32. DOI: https://doi.org/10.1016/j.echo.2009.09.028
  • Franco E, Almería C, de Agustín JA, Arreo Del Val V, Gómez de Diego JJ, García Fernández MÁ, Macaya C, Pérez de Isla L, García E. Three-Dimension al Color Doppler Transesophageal Echocardiography for Mitral Paravalvular Leak Quantification and Evaluation of Percutaneous Closure Success Jour- nal of American Society of Echocardiography 2014; 27 (11): 1153-1163. DOI: https://doi.org/10.1016/j.echo.2014.08.019
  • Cortés M, García E, García-Fernandez MA, et al. Usefulness of transesophageal echocardiography in percutaneous transcatheter repairs of paravalvular mitral regurgitation. American Journal of Cardiology 2008; 101 (3): 382-386. DOI: https://doi.org/10.1016/j.amjcard.2007.08.052
  • Nucifora G, Faletra FF, Regoli F, et al. Evaluation of the left atrial appendage with realtime 3-dimensional transesophageal echocardiography: implications for catheter-based left atrial appendage closure. Circulation Cardiovas- cular Imaging 2011; 4: 514-523. DOI: https://doi.org/10.1161/CIRCIMAGING.111.963892
  • Gafoor S, Schulz P, Heuer L, et al. Use of Echo-Navigator, a novel echocardiography-fluoroscopy overlay system, for transseptal puncture and left atrial appendage occlusion. Journal of Interventional Cardiology 2015; 28: 215-217. DOI: https://doi.org/10.1111/joic.12170
  • Jungen C, Zeus T, Balzer J, et al. Left atrial appendage closure guided by integrated echocardiography and fluoroscopy imaging reduces radiation exposure. Plos One 2015; 10: 1-13. DOI: https://doi.org/10.1371/journal.pone.0140386
  • García-Fernández M, De Agustín A, Pérez de Isla L. Eco-Xray fusion in left atrial appendage closure. Revista Española de Cardiología 2016. Article in press. DOI: https://doi.org/10.1016/j.rec.2016.05.020
  • Kempfert J, Noettling A, John M, et al. Automatically segmented Dyna-CT: enhanced imaging during transcatheter aortic valve implantation. Journal of American Collegue of Cardiology 2011; 58: e211. DOI: https://doi.org/10.1016/j.jacc.2011.05.065
  • Balzer J, Hall S, Rassaf T, et al. Feasibility, safety and efficacy of real-time three dimensional transoesophageal echocardiography for guiding device closure of interatrial communications: Initial clinical experience and impact on radiation exposure. European Journal of echocardiography 2010; 11: 1-8. DOI: https://doi.org/10.1093/ejechocard/jep116
  • Jone P, Ross M, Bracken J, et al. Feasibility and safety of using a fused echocardiography/Fluoroscopy imaging system in patients with congenital heart disease. Journal of American society of echocardiography 2016; 5: 13-21. DOI: https://doi.org/10.1016/j.echo.2016.03.014
  • Faletra FF, Pedrazzini G, Pasotti E, et al. Echocardiography-X-Ray Image Fu- sion. JACC Cardiovascular imaging 2016; 9 (9): 1114-1117. DOI: https://doi.org/10.1016/j.jcmg.2015.09.022
  • Avenatti E, Barker C, Little S. Tricuspid regurgitation repair with a Mitraclip device: transoesophageal echocardiography. Eur Heart J Cardiovasc Imaging 2017. Epub a head of print.
  • Muller D, Farivar R, Jansz P, et al. Transcatheter mitral valve replacement for patients with symptomatic mitral regurgitation. JACC 2017; 69: 381- 391. DOI: https://doi.org/10.1016/j.jacc.2016.10.068